Bulgaria – Medical consumables – Supply of medical devices for hemodialysis for the needs of MHAT "Dr. Tota Venkova" AD, Gabrovo
Supply of medical devices for hemodialysis for the needs of MHAT "Dr. Tota Venkova" AD, Gabrovo. The subject matter of this procurement will be referred to briefly in this documentation as “products”. described in detail in CHAPTER TECHNICAL SPECIFICATIONS 1.
Opportunity description
Supply of medical devices for hemodialysis for the needs of MHAT "Dr. Tota Venkova" AD, Gabrovo. The subject matter of this procurement will be referred to briefly in this documentation as “products”. described in detail in CHAPTER TECHNICAL SPECIFICATIONS 1. LOT – SOLUTIONS FOR BICARBONATE HEMODIALYSIS 1.01. ACID BICARBONATE HEMODIALYSIS CONCENTRATE - CHD A13 to A13.2, x 1 liter (Barrel PET of 5 lit.), solution for bicarbonate hemodialysis liter 35000 1.02. ACID BICARBONATE HEMODIALYSIS CONCENTRATE - CHD A13.6 to A14, x 1 liter (Barrel PET of 5 lit.), solution for bicarbonate hemodialysis liter 15000 1.03. BASIC BICARBONATE HEMODIALYSIS CONCENTRATE 8.4%, x 1 liter (Barrel PET of 6 lit.), solution for bicarbonate hemodialysis liter 25000 7. LOT – HEMOPERFUSORS. Housing material: polypropylene. Length 245mm. Maximum diameter 87mm. Absorbent: activated carbon. Absorbent covering material: cellulose. Membrane thickness between 3-5micro m. Filter pore size 450 micro m 7.01. HEMOPERFUSOR - filling volume 140ml. Total absorbent surface area 150m2; Housing material: polypropylene. Length 245mm. Maximum diameter 87mm. Absorbent: activated carbon. Absorbent covering material: cellulose. Membrane thickness between 3-5micro m. Filter pore size 450 micro m pcs. 1 7.02. HEMOPERFUSOR - filling volume 260ml. Total absorbent surface area 300m2; Housing material: polypropylene. Length 245mm. Maximum diameter 87mm. Absorbent: activated carbon. Absorbent covering material: cellulose. Membrane thickness between 3-5micro m. Filter pore size 450 micro m pcs. 3 8. LOT – LOW FLUX DIALYZERS for adults with surface areas: To be offered with the required active surface areas indicated in the specification, suitable for different patients. Membrane: made of Helixone. Housing: made of polycarbonate or another high-quality material resistant to external influences. They must have a design and structure allowing optimal filling with dialysis solution without unusable spaces. They must ensure excellent removal of low- and high-molecular-weight substances. They must have high antithrombogenicity, allowing the use of small doses of heparin. Sterilization method: inline steam (INLINE STEAM); Clearance at a blood flow rate of 300 ml/min and QF = 0 mL/min, specified in the table below: 8.01. LOW FLUX DIALYZER for adults - effective area 1.0 m2, clearance: KUF 8, Urea ml/min – 228, Creatinine ml/min – 200, Phosphates ml.min – 164, Vitamin B 12 – 94 ml/min, K0A Urea - 614 ml/min; To be offered with the required active surface areas indicated in the specification, suitable for different patients. Membrane: made of Helixone. Housing: made of polycarbonate or another high-quality material resistant to external influences. They must have a design and structure allowing optimal filling with dialysis solution without unusable spaces. They must ensure excellent removal of low- and high-molecular-weight substances. They must have high antithrombogenicity, allowing the use of small doses of heparin. Sterilization method: inline steam (INLINE STEAM); Clearance at a blood flow rate of 300 ml/min and QF = 0 mL/min pcs. 200 8.02. LOW FLUX DIALYZER for adults - effective area 1.4 m2, clearance: KUF 12, Urea ml/min – 254, Creatinine ml/min – 225, Phosphates ml.min – 194, Vitamin B 12 – 120 ml/min, K0A Urea - 874 ml/min; To be offered with the required active surface areas indicated in the specification, suitable for different patients. Membrane: made of Helixone. Housing: made of polycarbonate or another high-quality material resistant to external influences. They must have a design and structure allowing optimal filling with dialysis solution without unusable spaces. They must ensure excellent removal of low- and high-molecular-weight substances. They must have high antithrombogenicity, allowing the use of small doses of heparin. Sterilization method: inline steam (INLINE STEAM); Clearance at a blood flow rate of 300 ml/min and QF = 0 mL/min pcs. 800 8.03. LOW FLUX DIALYZER for adults - effective area 1.8 m2, clearance: KUF 14, Urea ml/min – 261, Creatinine ml/min – 231, Phosphates ml.min – 210, Vitamin B 12 –138 ml/min, K0A Urea - 976 ml/min; To be offered with the required active surface areas indicated in the specification, suitable for different patients. Membrane: made of Helixone. Housing: made of polycarbonate or another high-quality material resistant to external influences. They must have a design and structure allowing optimal filling with dialysis solution without unusable spaces. They must ensure excellent removal of low- and high-molecular-weight substances. They must have high antithrombogenicity, allowing the use of small doses of heparin. Sterilization method: inline steam (INLINE STEAM); Clearance at a blood flow rate of 300 ml/min and QF = 0 mL/min pcs. 6000 8.04. ANTIBACTERIAL FILTER. It must provide dialysis solution free of bacteria, endotoxins and pyrogens in accordance with the requirements of the "Dialysis Treatment" standard and with the Fresenius 4008 S and Classic machine. pcs. 120 11. LOT - CATHETER SET 11.01. CATHETER SET SIZE M - CONNECTION KIT: drape 30cm./40cm. -1 pc., nitrile gloves size M - 2 pcs., self-adhesive dressing 10cm./10cm. - 1 pc., alcohol swabs with chlorhexidine - 4 pcs., adhesive strips 2.5cm./15cm. - 2 pcs., nonwoven compresses 7.5cm./7.5cm. - 4 pcs. AND DISCONNECTION KIT: Nitrile gloves size M - 2 pcs., protective catheter bag - 1 pc., caps for an intravenous cannula with a built-in injection port - 2 pcs., alcohol swabs with chlorhexidine - 2 pcs., nonwoven compress 7.5cm./7.5cm. - 2 pcs. pcs. 4000 11.02. CATHETER SET SIZE L - CONNECTION KIT: drape 30cm./40cm. - 1 pc., nitrile gloves size L - 2 pcs., self-adhesive dressing 10cm./10cm.- 1 pc., alcohol swabs with chlorhexidine- 4 pcs., adhesive strips 2.5cm./15cm. - 2 pcs., nonwoven compresses 7.5cm./7.5cm. - 4 pcs. AND DISCONNECTION KIT: Nitrile gloves size L - 2 pcs., protective catheter bag - 1 pc., caps for an intravenous cannula with a built-in injection port - 2 pcs., alcohol swabs with chlorhexidine - 2 pcs., nonwoven compress 7.5cm./7.5cm. - 2 pcs. pcs. 1500 ITEM – BLOOD LINES. They must provide the blood flow required to perform effective dialysis treatment. Reliable and secure construction, eliminating the risk of blood loss due to leaks. Secure and safe connection to the dialyzer through a "luer"-type connector. They must be made of medical-grade PVC. 16 BLOOD LINES: They must be equipped with an infusion system and a venous blood-line chamber diameter of 22 mm. Conical needle design (Pencil Point), to avoid bending when piercing bags. They must be equipped with clamps of the corresponding color - red and blue. Length of the arterial blood line from 3.7 m. to 4.0 m. Length of the venous blood line from 2.7 m. to 3.0 m. The kit must include a bag for collecting the saline solution used to flush the blood lines before starting hemodialysis. They must provide the blood flow required to perform effective dialysis treatment. Reliable and secure construction, eliminating the risk of blood loss due to leaks. Secure and safe connection to the dialyzer through a "luer"-type connector. They must be made of medical-grade PVC. set 10000 ITEM – OTHER MEDICAL DEVICES AND PREPARATIONS FOR HEMODIALYSIS 23 ANTIBACTERIAL SOLUTION for filling dialysis catheters: Natrium citricum 4%, Taurolidine 1% Heparin 500 e/ml- solutio 10ml vial 2500 Procedure: open. Estimated value: 304,965.9 EUR. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.