Germany – Construction work – intended call for tenders Drebkauer Straße 69 - 70
In this context, the comprehensive modernization and repair of the two exist- ing residential buildings at Drebkauer Straße 69 and Drebkauer Straße 70 will be carried out. Structural work / clearing/dismantling/deconstruction / non-load-bearing interior walls, wall linings
Opportunity description
In this context, the comprehensive modernization and repair of the two exist- ing residential buildings at Drebkauer Straße 69 and Drebkauer Straße 70 will be carried out. Structural work / clearing/dismantling/deconstruction / non-load-bearing interior walls, wall linings ? Clearing of the common areas (basement, stairwell, attic, etc.) ? Dismantling of existing built-in fixtures in all residential units, such as suspended storage platforms, built-in cupboards, shelving, etc., as well as removal of existing equipment such as kitchen stoves, heating and hot-water generators (boilers), sanitary equipment, existing furnishings, etc. ? Dismantling of the existing building installations (sanitary, heating and electrical) ? Removal of floor finish layers or coverings and all skirting boards ? Removal of existing wall and ceiling coverings (wallpaper, tiles, paneling) ? Alteration work to improve apartment layouts: partial demolition of interior walls, crea- tion, adjustment and closure of door openings, partial demolition of window parapets for the installation of new balcony French doors ? new interior walls in the apartments as metal stud wall constructions in various wall thicknesses, double-clad with gypsum plasterboards, with core insulation boards, filled; in bathrooms, approved boards for bathroom areas in domestic housing ? Wall-mounted installations, cladding of building services systems and pipe casings in various thicknesses, in coordination with the HVAC building services planner, inspection openings in accordance with plan- ning progress Windows ? Replacement of window units with tilt-and-turn windows, execution in accordance with the design, building-physics and sound-insulation calculations, made of plastic ? new interior window sills ? Exterior window sills in accordance with the design, made of aluminum sheet, RAL powder-coated, or natural stone Building entrance doors ? Aluminum door units with glazed sections in accordance with the building-physics calculation ? Mailbox and communication system (doorbell panel, intercom system and, if applicable, camera eye) as well as illuminated house number Apartment entrance doors ? tightly closing and self-closing single-leaf door units made of wood-based materials with laminate coating, with matching wraparound frames/ lining frames, meeting sound insulation, fire protec- tion and security requirements, equipped with a "peephole", overhead door closer, among other things, in accordance with the design/ sample selec- tion and room book/APL Interior apartment doors ? Single-leaf door units, made of wood-based materials with laminate coating, with matching wraparound frames/ lining frames, in accordance with the design/ sample selection and room book/APL Basement door units ? Replacement of the door units between basement rooms and the stairwell with fire doors, self-closing, smoke-tight, equipment in accordance with fire-protection requirements ? Construction of storage rooms for tenants of the new building ? Tenant basement doors as steel mesh or wooden-slat doors Wall and floor coverings, wall/ceiling coatings ? Surface quality and colored coating of walls and ceilings in accordance with the design/ sample selec- tion and room book/APL ? Bathroom/WC: floor tiles and wall tiles in the shower/bathtub area (full room height), in the wet area (washbasin, WC, washing machine, H approx. 1.25m) in accordance with the design/ sample selection and room book/APL ? Linoleum floor coverings or similar in accordance with the design/ sample selection and room book/APL Balconies ? projecting balcony systems (courtyard side) as steel/aluminum column/ precast slab construction with concrete strip foundations, foundation size and profile dimensions in accordance with structural require- ments; all steel/aluminum profiles hot-dip galvanized and RAL powder-coated, in accordance with the design/ sample selection/APL ? raised balcony floor coverings as decking (e.g. synthetic wood decking boards) on resiliently supported load-bearing profiles for an accessible transition between living areas and balconies (height differ- ence max. 2cm, clear door width min. 90cm), channel with grid-like surface in the area of the balcony exit doors (splash protection/drainage) ? Railings made of steel/aluminum profile construction, railing infill made of prefinished plastic or aluminum panels or laminated safety glazing ? Drainage through internal floor drain with drainpipe or box gutter, separate downpipe with infiltration into the grounds or connection to the drainage system KG 400 / STRUCTURE - Technical installations Wastewater and water systems ? Drinking-water supply from the public utility's drinking-water network (LWG) via exist- ing building connections, separate water-meter system in the building connection room ? New installation of drinking-water pipe network (from the building water meter) made of stainless steel up to the residential-unit distributor, instal- lation of building water station consisting of backwash filter and shut-off valves ? Wastewater discharge (separate from precipitation water) via collection pipes behind wall linings or in installation walls to downpipes within sanitary shafts containing all media-carrying lines for the building-services supply and disposal systems; ventilation of the downpipes by means of main vents above the roof; connection of the downpipes to existing/renewed wastewater under- ground pipes in the basement ? Downpipes and collection pipes as well as vent lines made of sound-insulated plastic pipe (dB20), with approved F90 firestops in the floor slabs ? Ventilation above the roof with vent cowls or combined cowl systems for exhaust air and wastewater; vent lines on the top floor with condensation insulation Connections for the sanitary fixtures within the residential units in wall-mounted installations with HT pipe including sound insulation or Silent-PP pipe (multilayer composite pipe); shut-off valves and consumption metering equipment (water meters) for each apartment outlet (concealed installation) ? Bathroom equipment: flat shower and/or bathtub with tub support, with surface-mounted thermostatic mixer with shower set and holder; shower enclosures made of aluminum profiles with plastic glazing; washbasin (60cm) with deck-mounted lever mixer; wall-hung washdown WC with dual-flush actuation ? Kitchen equipment: necessary supply and disposal connections Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.