Germany – Construction work for buildings relating to health – New construction of kbo-Inn-Salzach-Klinikum - Construction of care building BT C + D - 107_3-4101 Sanitary BT C+D
New construction of kbo-Inn-Salzach-Klinikum - Construction of care building BT C + D Building section C 1.950 m SML drainage pipes DN 50 - DN 200 100 m PE-HD drainage pipes DN 50 - DN 100 2 units Double lifting systems containing fecal matter 300 m rainwater pipes steel ve
Opportunity description
New construction of kbo-Inn-Salzach-Klinikum - Construction of care building BT C + D Building section C 1.950 m SML drainage pipes DN 50 - DN 200 100 m PE-HD drainage pipes DN 50 - DN 100 2 units Double lifting systems containing fecal matter 300 m galvanized steel rainwater pipes DN 70 32 units Rainwater roof drains 50 units Wastewater roof penetrations 6.000 m stainless steel pipe DN 12 - DN 80 150 units Inclined-seat valves DN 12 - DN 80 200 units Concealed shut-off valves DN 12 - DN 20 90 units Circulation regulating valves (static + thermal) 2 units Water softening systems 40 units Toilet systems 80 units Washbasin systems 5 units Shower systems 3 units Urinal systems 3 units Relaxation baths 10 units Slop sink systems 15 units Kitchen systems 50 units Wall-mounted fittings 800 m Thermal insulation (mineral wool) in service walls 4 units Dry fire-extinguishing lines incl. outlet points + feed 1 unit Toilet container for own trade incl. maintenance 1 unit Toilet container for other trades incl. maintenance 600 units Fire-protection penetrations for drinking water DN 12 - DN 80 480 units Fire-protection penetrations for wastewater DN 50 - DN 150 Building section D 1.650 m SML drainage pipes DN 50 - DN 200 100 m PE-HD drainage pipes DN 50 - DN 100 2 units Double lifting systems containing fecal matter 250 m galvanized steel rainwater pipes DN 70 32 units Rainwater roof drains 45 units Wastewater roof penetrations 4.700 m stainless steel pipe DN 12 - DN 80 140 units Inclined-seat valves DN 12 - DN 80 180 units Concealed shut-off valves DN 12 - DN 20 90 units Circulation regulating valves (static + thermal) 2 units Water softening systems 27 units Toilet systems 50 units Washbasin systems 5 units Shower systems 3 units Urinal systems 3 units Relaxation baths 10 units Slop sink systems 15 units Kitchen systems 50 units Wall-mounted fittings 600 m Thermal insulation (mineral wool) in service walls 4 units Dry fire-extinguishing lines incl. outlet points + feed 1 unit Toilet container for own trade incl. maintenance 1 unit Toilet container for other trades incl. maintenance 500 units Fire-protection penetrations for drinking water DN 12 - DN 80 400 units Fire-protection penetrations for wastewater DN 50 - DN 150 Procedure: open. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.