Germany – Construction work – Lot 406: Refrigeration systems, split air conditioning - New Medical Center 2.0, Hansenstraße in Barleben
Lot 406: Refrigeration systems, split air conditioning - New Medical Center 2.0, Hansenstraße in Barleben The contracting authority, the Municipality of Barleben, is planning the construction of a new medical center with 5 practices at Hansenstraße 42 in 39179 Barleben. The attic also contains sto
Opportunity description
Lot 406: Refrigeration systems, split air conditioning - New Medical Center 2.0, Hansenstraße in Barleben The contracting authority, the Municipality of Barleben, is planning the construction of a new medical center with 5 practices at Hansenstraße 42 in 39179 Barleben. The attic also contains storage rooms for the tenants. The building consists of a ground floor, an upper floor and an attic. It will not have a basement. The building stands detached on the property. The new building will be constructed as a conventional masonry structure with reinforced-concrete ceilings and a pitched roof. The roof will be constructed as a traditional timber structure with tile covering and thermal insulation. The stability of the building will be ensured by adequately dimensioned wall and floor diaphragms. The foundation will consist of a reinforced-concrete floor slab with continuous strip foundations / frost aprons. The construction site will be accessible via Ernst-Thälmann-Straße and Hansenstraße. Access to the construction site will be via the future property entrance located to the southeast. IT IS STRONGLY ADVISED TO INSPECT THE SITE BEFORE SUBMITTING A TENDER. Address: Hansenstraße 42 · 39179 Barleben Entry onto the property must be arranged in advance by telephone. Please note that an inspection of the property will take place during the period from: 31.08.-25.09.2026! Please arrange an appointment in advance by calling: +49 39203 565-2965. Failure to provide a confirmed on-site inspection certificate will necessarily result in exclusion! Approximate quantities: - 4 - VRF multi-split systems (outdoor units) between approx. 5 - 15 kW - 28 indoor units as ceiling cassettes - 28 remote controls - 1 x system with outdoor unit and 3.5 kW wall-mounted unit for server room - approx. 500 m refrigerant lines, 6 to 16 mm, made of copper pipe, incl. insulation - approx. 160 m condensate lines DN 32 - DN 40 - approx. 400 m electrical cables incl. the required electrical connections Procedure: open. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.