Germany – Electrical wiring and fitting work – Heidelberg, University Hospital, Renovation and Subsequent Use of Forensic Medicine / HeiCINN Electrical, Safety and Information Technology Systems
Electrical, safety and information technology systems Renovation of reinforced concrete building, high-rise building, square floor plan, with attached low-rise building, consisting of 2 basement levels, underground car park and basement, as well as ground floor, 1st floor–6th floor, attic with tech
Opportunity description
Electrical, safety and information technology systems Renovation of reinforced concrete building, high-rise building, square floor plan, with attached low-rise building, consisting of 2 basement levels, underground car park and basement, as well as ground floor, 1st floor–6th floor, attic with technical center Low-voltage switchgear AV 6 panels 1630 A Low-voltage switchgear SV 6 panels 1630 A 1100 m halogen-free cable N2XCH 4*240SM/120 800 m cable NHXCHFE180 4*150RM/70 40 m² raised floor 1 unit UPS system 80 kVA 340 m halogen-free cable N2XCH 4*95SM/ 50 240 m halogen-free cable N2XCH 4*50 SM / 25 200m cable N2XH J 1 * 25 RM 2595 m NHXMH-J 5 *6 RE 1570 m NHXMH-J 5* 4 RE 1570 m NHXMH-J 5 * 2.5 RE 10030 m NHXMH-J 5* 1.5 RE 21650 m NHXMH-J 3 * 2.5 RE 10095 m NHXMH-J 3*1.5 RE 15 sub-distribution boards 125 A H/W/D 1850(+100) * 800 *225 special color 15 sub-distribution boards 160 A H/W/D 1850(+100) * 800 *225 special color 5 sub-distribution boards 250 A H/W/D 1850(+100) * 800 *225 special color 875 protective-contact sockets 328 protective-contact sockets with hinged cover KNX blind control with 193 KNX push-buttons and 35 blind roller-shutter actuators, 4-gang 321 m perforated cable tray H 60 W 200 with special fastening 190 m cable tray H 60 W 300 with special fastening due to structural requirements 170 m cable tray H 100 W 300 with special fastening due to structural requirements 301 m cable tray H 60 W 400 with special fastening due to structural requirements 890 luminaires in various designs 1 unit emergency lighting device 1 h 6.5 kW 16000 m data cable Cat 7A 325 data connection sockets 11 IT 19 " distributors 43 U 950 m E 30 fire alarm cable JE-H(St)H 2*2*0.8 Extend primion access control system with 39 readers Procedure: open. Estimated value: 4,195,512.94 EUR. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.