Germany – Installation work of illumination and signalling systems – New construction of the Fire Protection and Training Center (BAZ) at the Newel site
General description: The Trier-Land collective municipality is planning the construction of a central fire protection and training center in Newel in order to consolidate the interregional functions of the collective municipality fire brigade, make use of synergies and increase the op
Opportunity description
General description: The Trier-Land collective municipality is planning the construction of a central fire protection and training center in Newel in order to consolidate the interregional functions of the collective municipality fire brigade, make use of synergies and increase operational readiness. In the future, the building is intended to provide space not only for the secure accommodation of vehicles, but also for the storage and organization of a wide range of equipment. In addition to the facilities mentioned, training and meeting rooms will be provided, not only for regular training sessions and information on new techniques, regulations and deployment strategies, but also for the central initial and continuing training of the fire brigade personnel throughout the Trier-Land collective municipality. The training area will be completed by a training yard and a training wall specially designed for practical instruction and training. The fire brigade’s workshop areas will be supplemented by additional office and workshop areas of the collective municipality (municipal works yard, forestry special-purpose association) in order to cover a broader range of inspection, maintenance and repair work. The ground floor and the upper floor of the two-story building structure are planned as a solid reinforced-concrete structure with a high degree of prefabrication. The exterior walls consist of reinforced-concrete cavity walls, will be thermally insulated and will receive an aluminum curtain wall with freely designed profile geometry. The vehicle hall is to be constructed as a conventional reinforced-concrete frame structure. The partition wall between the vehicle hall and the adjoining ancillary-room program is planned as a thermally insulated reinforced-concrete wall. Inside, the reinforced-concrete cavity walls are predominantly intended to remain exposed. The roof structure, in the form of a green roof with a PV system, rests on reinforced-concrete girders and consists of a load-bearing trapezoidal-sheet shell as a warm-roof construction, with acoustic perforations on its underside. The subject of this invitation to tender is work for an emergency lighting system as a self-contained battery system. The work comprises the supply, installation and commissioning of a radio-based automatic testing and control system as well as approximately 70 emergency and escape sign luminaires (of which approximately 26 escape sign luminaires, approximately 22 emergency luminaires for a vehicle hall, approximately 8 luminaires for surface mounting, approximately 12 luminaires for recessed mounting and approximately 14 outdoor luminaires with protection rating IP65). An additional subject of this invitation to tender is the conclusion of a maintenance contract in accordance with AMEV with a term of 4 years. Emergency lighting as a self-contained battery system - Radio-based automatic testing and control system - Approx. 26 units escape sign luminaires - Approx. 22 units emergency luminaires, vehicle hall - Approx. 8 units emergency luminaires, surface mounting - Approx. 12 units emergency luminaires, recessed mounting - Approx. 14 units emergency luminaires, outdoor – IP65 Maintenance contract in accordance with AMEV - Term 4 years The subject of this invitation to tender is work for an emergency lighting system as a self-contained battery system. The work comprises the supply, installation and commissioning of a radio-based automatic testing and control system as well as approximately 70 emergency and escape sign luminaires (of which approximately 26 escape sign luminaires, approximately 22 emergency luminaires for a vehicle hall, approximately 8 luminaires for surface mounting, approximately 12 luminaires for recessed mounting and approximately 14 outdoor luminaires with protection rating IP65). An additional subject of this invitation to tender is the conclusion of a maintenance contract in accordance with AMEV with a term of 4 years. Emergency lighting as a self-contained battery system - Radio-based automatic testing and control system - Approx. 26 units escape sign luminaires - Approx. 22 units emergency luminaires, vehicle hall - Approx. 8 units emergency luminaires, surface mounting - Approx. 12 units emergency luminaires, recessed mounting - Approx. 14 units emergency luminaires, outdoor – IP65 Maintenance contract in accordance with AMEV - Term 4 years Procedure: open. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.