Germany – Installation work of refrigeration equipment – Heidelberg, University Hospital, Renovation and Subsequent Use of Forensic Medicine / HeiCINN Ventilation and Air-Conditioning Systems DIN 18379
Ventilation and air-conditioning systems DIN 18379 Renovation of reinforced concrete building, high-rise building, with surrounding escape balconies, square floor plan, with attached low-rise buildings, consisting of 2 basement levels, underground car park and basement, as well as ground floor, 1st floor to 6th floor, attic sto
Opportunity description
Ventilation and air-conditioning systems DIN 18379 Renovation of reinforced concrete building, high-rise building, with surrounding escape balconies, square floor plan, with attached low-rise buildings, consisting of 2 basement levels, underground car park and basement, as well as ground floor, 1st floor to 6th floor, attic with central plant room - ventilation and air-conditioning system with cooling and heating coils, sound attenuators, heat recovery, with run-around coil system incl. pumping station and all hydraulic components, filters, etc. 30,000 m³/h. Supply and exhaust air locally separated. - Supply/exhaust ventilation and air-conditioning system with cooling and heating coils, humidification, sound attenuators, heat recovery, filters, etc. 6,500 m³/h. - Supply/exhaust ventilation and air-conditioning system with cooling and heating coils, sound attenuators, heat recovery, filters, steel spring vibration isolators, etc. 6,000 m³/h. - Two supply/exhaust air-conditioning cabinet ventilation and air-conditioning systems with cooling and heating coils, filters, etc. 2,700 m³/h. - Special exhaust-air system with two parallel plastic fans, with sound-insulation enclosure, filters, louvre and control dampers, etc. 4,000 m³/h each. - Compact supply/exhaust ventilation and air-conditioning system with heating coil, ceiling mounting, sound attenuators, heat recovery, filters, etc. 550 m³/h. - Outdoor-air and exhaust-air towers, diameter approx. 1.5 m, total height approx. 3.7 m, for 33,000 m³/h - Combined outdoor-air intake and exhaust-air tower Ø1600 mm, total height approx. 5.5 m, for 10,000 m³/h - Outdoor-air and exhaust-air towers, diameter approx. 0.7 m, total height approx. 4 m, for 5,000 m³/h - 5,344 m² galvanized steel air ducts and fittings, edge length 0 to over 2,000 mm - approx. 1,500 m galvanized steel spiral-seam pipe DN 80 to DN 355 incl. fittings, other components and fastenings - approx. 650 m² PPS air ducts and fittings, rectangular, edge length 0 to over 2,000 m - approx. 750 m PP pipe, galvanized steel, OD 75 to DN 500 incl. fittings, components and fastenings - approx. 180 BSK rectangular or round, electronically controlled, various sizes - approx. 430 VSR constant, approx. 150 VSR variable, rectangular or round, various sizes - approx. 277 SD round, and approx. 25 splitter SD rectangular, various sizes - approx. 400 outlets, various types and sizes Procedure: open. Estimated value: 3,002,498.41 EUR. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.