Germany – Painting work of buildings – New Construction of Geradstetten Education Center - Painting and Floor Coating
New Construction of Geradstetten Education Center - Painting and Floor Coating PREPARATORY MEASURES - Clean wall surface substrates of coarse dirt m² 2325 - Remove concrete and mortar burrs, dimensions up to 30 x 30 mm m 10 - Plaster chases
Opportunity description
New Construction of Geradstetten Education Center - Painting and Floor Coating PREPARATORY MEASURES - Clean wall surface substrates of coarse dirt m² 2325 - Remove concrete and mortar burrs, dimensions up to 30 x 30 mm m 10 - Plaster chases m 50 - Plaster defective areas St 25 - Epoxy resin grout kg 30 - Clean ceiling surface substrates of coarse dirt m² 225 - Structural ceiling substrate m² 560 - Cut off protruding perimeter insulation strips, PE foam m 2200 - Moisture measurement St 20 - Check pull-off strength, delimit test areas St 20 - Monitoring of application conditions and dew point psch 1 - Verification of layer thicknesses, non-destructive St 3 - Substrate preparation (milling high points) m² 20 - Prepare floor surface substrates / shot-blasting m² 325 - Prepare floor surface substrates / grinding / vacuuming m² 60 - Application on flight of stairs. m² 160 - Coatable waterproofing, 1-component polymer dispersion m² 26 - Waterproofing connection m 30 - Seal around on-site floor drains St 3 WALL SURFACES - Primer - concrete wall surfaces m² 57 - Primer, solid masonry walls m² 5 - Filling concrete walls m² 57 - Filling solid masonry walls m² 5 - Dispersion coating NAB 2 white - solid wall surfaces m² 22 - Dispersion coating NAB 2 red 3 - concrete wall surfaces m² 40 - Primer - drywall wall surfaces m² 7170 - Primer, reveals at openings and niches m² 130 - Filling drywall wall surfaces, from Q2 to Q3 m² 7170 - Filling reveals at openings and niches m² 130 - Dispersion coating NAB 2 white - drywall wall surfaces m² 5320 - Dispersion coating NAB 2, reveals at openings and niches m 50 - Dispersion coating NAB 2 green 3 - drywall wall surfaces m² 1260 - Dispersion coating NAB 2 red 3 - drywall wall surfaces m² 590 - Dispersion coating NAB 2, reveals at openings and niches m 715 - Primer - drywall wall surfaces m² 290 - Filling drywall wall surfaces, from Q2 to Q3 m² 290 - Dispersion latex coating NAB 1 green 1 - drywall wall surfaces in WC rooms m² 170 - Dispersion latex coating NAB 1 red 1 - drywall wall surfaces in WC rooms m² 120 - Skirting strips, 2-component PUR coating on wall surfaces, transparent m 930 - Skirting strips, 2-component PUR coating on gypsum-board wall surfaces, white m 930 CEILING SURFACES - Coating of installations below the ceiling surface in the foyer + cafeteria, incl. primer m² 560 - Primer - smooth drywall ceiling surfaces m² 740 - Filling smooth drywall ceiling surfaces, from Q2 to Q3 m² 740 - Dispersion coating NAB 2 white - smooth and perforated drywall ceiling surfaces m² 300 - Vertical surfaces of smooth drywall ceiling bulkheads m² 90 - Surcharge for inspection hatches, dispersion coating NAB 2 white St 44 - Dispersion coating NAB 2 green 3 - smooth drywall ceiling surfaces m² 420 - Dispersion coating NAB 2 red 3 - smooth drywall ceiling surfaces m² 150 - Surcharge for inspection hatches, dispersion coating NAB 2 St 115 - Primer - concrete ceiling surfaces m² 50 - Preliminary filling of concrete ceiling surfaces m² 50 - Termination profile / lateral wall connections m 30 - Bond acoustic plaster carrier board, A1, d = 25 mm m² 50 - 1st acoustic plaster coating m² 50 - 2nd acoustic plaster coating m² 50 - Cutout / work around round fixtures with DM = approx. 90-200 mm? St 2 - Cutout / work around hangers St 85 FLOOR SURFACES - 2-component epoxy resin sealer incl. primer - stair landings m² 55 - SMF west staircase m² 27 - SMF east staircase m² 39 - GHV south staircase m² 45 - GHV north staircase m² 45 - Surcharge for slip resistance m² 160 - Surcharge for initial maintenance treatment m² 211 - 2-component EP sealer incl. primer m² 142 - 2-component EP sealer - skirting surfaces m 130 - Surcharge for slip resistance m² 142 - Primer under ECC coating - floor surfaces m² 73 - Primer under EEC coating - skirting surfaces m² 90 - Cement-based ECC filling - floor surfaces m² 73 - EEC filling - skirting surfaces m 90 - 2-component EP-ESD coating incl. primer m² 73 - 2-component EP-ESD coating - skirting surfaces m 90 - Surcharge for slip resistance m² 73 - Conductive set, connection points for grounding St 22 - Earth leakage resistance measurements St 11 - Primer under scratch coat - floor surfaces m² 105 - EP scratch coat - floor surfaces m² 105 - Cove / skirting formation m 150 - Cove corner formation St 60 - Work coves around frames St 13 - PUR jointing of cove profiles - special color m 150 - 2-component EP self-leveling coating incl. primer m² 105 - 2-component EP self-leveling coating - skirting surfaces/coves m 150 - PUR top sealer m² 105 - Surcharge for slip resistance m² 105 - PUR top sealer - skirting surfaces/coves m 150 - Work up to uncoated surfaces m 20 COATINGS ON METAL - Coating of electrical distribution board fronts H/W = approx. 0.40/0.35 m, red 3 St 33 OTHER MEASURES - PU joint up to 10 mm m 250 - PU jointing 10-20 mm, application in stairwell m 200 - Backfill material for permanently elastic joint m 200 - Acrylic jointing of connection joints, w = approx. 5-10 mm m 1000 - Silicone jointing of connection joints, w = approx. 5-10 mm m 100 - Special protective measures, dust-tight masking m² 250 - Plastic-sheet dust-protection door with zipper, approx. 210 x 110 cm St 3 - Protective covering, painter's fleece, floor m² 100 - Remove and dispose of painter's fleece m² 100 - Protective covering, hardboard panels, floor m² 35 - Remove and dispose of hardboard panels m² 35 Procedure: open. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.