Germany – Ventilation installation work – Renovation of School Center, Construction Phase 4_Ventilation, Construction Phase 4
Construction Phase 4 comprises the renovation of the middle school wing, the administration areas of the primary and middle schools, and the upper floor of the primary school area Construction Phase 4 comprises the renovation of the middle school wing, the administration areas of the primary and middle schools, and the upper floor of the primary school area Main servi
Opportunity description
Construction Phase 4 comprises the renovation of the middle school wing, the administration areas of the primary and middle schools, and the upper floor of the primary school area Construction Phase 4 comprises the renovation of the middle school wing, the administration areas of the primary and middle schools, and the upper floor of the primary school area Main services are: - approx. 1 supply and exhaust air unit, outdoor installation, with heat recovery, 30,000 m³/h - approx. 1 supply and exhaust air unit, outdoor installation, with heat recovery, 12,000 m³/h - approx. 1 supply and exhaust air unit, outdoor installation, with heat recovery, 27,000 m³/h - approx. 1 supply and exhaust air unit, outdoor installation, with heat recovery, 5,000 m³/h - approx. 4 steel frames for equipment installation on flat roof - approx. 35 roof curbs for duct penetrations through flat roof - approx. 8,400 m² rectangular galvanized ventilation ducting - approx. 770 m round galvanized ventilation ducting DN100-DN300 - approx. 40 m round PP ventilation ducting DN100-DN250 - approx. 40 m² fire protection cladding - approx. 40 round fire dampers - approx. 35 rectangular fire dampers - approx. 70 rectangular fire dampers with smoke detectors - approx. 15 mechanical rectangular volume flow controllers - approx. 140 mechanical round volume flow controllers - approx. 130 motorized rectangular volume flow controllers - approx. 30 motorized round volume flow controllers - approx. 15 duct-mounted silencers - approx. 180 pipe-mounted silencers (telephone silencers) - approx. 1 modification of IT split air-conditioning unit - approx. 160 disc valves - approx. 520 ventilation grilles - approx. 80 swirl diffusers - Dismantling / disposal Procedure: open. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.