Romania – Oxygen – Purchase of medical oxygen and other medical gases
Purchase of medical oxygen and other medical gases According to the CS prepared, the following is envisaged through the conduct of the present procedure: a) the supply of medical oxygen and other medical gases, a purchase that also includes transport and the related rentals of the containers nec
Opportunity description
Purchase of medical oxygen and other medical gases According to the CS prepared, the following is envisaged through the conduct of the present procedure: a) the supply of medical oxygen and other medical gases, a purchase that also includes transport and the related rentals of the containers necessary for delivery of the products, under the conditions and in the quantities specified in the CS and in the procurement documents; b) the construction of an automatic backup station; a) the supply of medical oxygen and other medical gases, a purchase that also includes transport and the related rentals of the containers necessary for delivery of the products, under the conditions and in the quantities specified in the CS and in the procurement documents; The products will be supplied in compliance with the conditions and requirements contained in the CS, the supply of oxygen with a minimum active concentration of 99.5% in the following variants, as well as the supply of carbon dioxide as follows: Liquid oxygen in a 5,000 Nmc storage tank Compressed oxygen gas in 10 Nmc cylinders (50 L) Liquid oxygen in 500 Nmc LPT Compressed oxygen gas in 0.4 Nmc cylinders (2 L) Compressed oxygen gas in 1 Nmc cylinders (5 L) Compressed oxygen gas in 2 Nmc cylinders (10 L) Carbon dioxide in 37.5 kg cylinders Carbon dioxide in 15 kg cylinders Biogon C (carbon dioxide) 37.5 kg Biogon C (carbon dioxide) 15 kg Acetylene in 6 kg cylinders Entonox 10 L cylinder UPU Nitrogen cylinder N2 5.0 50 L Purity 99.999% Forensic Medicine Hydrogen cylinder H2 5.0 50 L Purity 99.999% Forensic Medicine Synthetic Air N2 5.0 50 L Purity 99.999% Forensic Medicine Medical oxygen, in the forms specified above, carbon dioxide, biogon (carbon dioxide) and acetylene will be provided for the 9 locations indicated in the CS. b) construction of an automatic backup station; In addition to the actual supply of the products identified above, tenderers in the procedure shall consider the design and installation/commissioning of 1 automatic backup station to provide the necessary backu-up in the event of failure of the existing storage/production stations at the SCJUA locations. In this regard, the design and construction of automatic backup stations under the following conditions are envisaged: 1. backup station (representing an installation with 2 X 10 cylinders) at the headquarters of the Arad County Clinical Emergency Hospital, Andrenyi Karoly Street, no. 2 - 4, Arad County General characteristics of the station: -it will be intended for use in departments as a backup station -it will provide a continuous flow of medical gases from cylinders having equal capacities and high pressure; -it will be provided with an emergency branch in the event that the two branches (main and secondary) are damaged or empty; -it will have an electronic system for monitoring the station’s operational parameters and for warning/alarming in the event of malfunction; -it will have a galvanized metal housing integrating first-stage pressure reducers, a secondary bypass pressure reducer, isolation valves, overpressure valves, pressure gauges and an alarm system. Technical data: -in accordance with HTM02-01, ISO 7396-1 standards; -suitable for 02, N2O, CO2, Air, N2; -two-stage pressure reduction system, in accordance with ISO 10524-2; -automatic switching from the active branch to the backup branch; -microprocessor-controlled alarm system, in accordance with HTM02-01; -all components that could be exposed to cylinder pressure are tested for resistance to fire-retardant factors, in accordance with ISO 10524-2 and ISO 15001. Number of days before the deadline for submission of tenders/applications by which clarifications may be requested: 18 days The contracting authority will respond clearly and completely to all requests for clarification on the 11th day before the deadline for submission of tenders. Purchase of medical oxygen and other medical gases According to the CS, the following is envisaged through the conduct of the present proc: a) the supply of medical oxygen and other medical gases, a purchase that also includes transport and the related rentals of the containers necessary for delivery of the products, under the conditions and in the quantities specified in the CS and in the procurement documents; b) the construction of an automatic backup station; a) the supply of medical oxygen and other medical gases, a purchase that also includes transport and the related rentals of the containers necessary for delivery of the products, under the conditions and in the quantities specified in the CS and in the procurement documents; The products will be supplied in compliance with the conditions and requirements contained in the CS, the supply of oxygen with a minimum active concentration of 99.5% in the following variants, as well as the supply of carbon dioxide as follows: Liquid oxygen in a 5,000 Nmc storage tank Compressed oxygen gas in 10 Nmc cylinders (50 L) Liquid oxygen in 500 Nmc LPT Compressed oxygen gas in 0.4 Nmc cylinders (2 L) Compressed oxygen gas in 1 Nmc cylinders (5 L) Compressed oxygen gas in 2 Nmc cylinders (10 L) Carbon dioxide in 37.5 kg cylinders Carbon dioxide in 15 kg cylinders Biogon C (carbon dioxide) 37.5 kg Biogon C (carbon dioxide) 15 kg Acetylene in 6 kg cylinders Entonox 10 L cylinder UPU Nitrogen cylinder N2 5.0 50 L Purity 99.999% Forensic Medicine Hydrogen cylinder H2 5.0 50 L Purity 99.999% Forensic Medicine Synthetic Air N2 5.0 50 L Purity 99.999% Forensic Medicine Medical oxygen, in the forms specified above, carbon dioxide, biogon (carbon dioxide) and acetylene will be provided for the following SCJUA departments/locations: 1. Departments at the hospital’s central headquarters (2 - 4 Andrenyi Karoly St.) – permanent operating regime - liquid oxygen in a 5,000 Nmc storage tank - compressed oxygen gas in 10 Nmc cylinders - compressed oxygen gas in 1 Nmc cylinders with pressure reducer - compressed oxygen gas in 2 Nmc cylinders with pressure reducer - carbon dioxide in 37.5 kg cylinders - carbon dioxide in 15 kg cylinders - Biogon C (carbon dioxide) 37.5 kg - Biogon C (carbon dioxide) 15 kg - Nitrogen cylinder N2 5.0 50 L Purity 99.999% Forensic Medicine - Hydrogen cylinder H2 5.0 50 L Purity 99.999% Forensic Medicine - Synthetic Air cylinder 5.0 50 L Purity 99.999% Forensic Medicine 2. Departments in Mihai Viteazul Square — permanent operating regime - liquid oxygen in a 5,000 Nmc storage tank - liquid oxygen in 500 Nmc LPT - compressed oxygen gas in 10 Nmc cylinders - compressed oxygen gas in 1 Nmc cylinders with pressure reducer - compressed oxygen gas in 2 Nmc cylinders with pressure reducer - carbon dioxide in 37.5 kg cylinders - carbon dioxide in 15 kg cylinders - Biogon C (carbon dioxide) 37.5 kg - Biogon C (carbon dioxide) 15 kg 3. TBC Department Sir. Stepban Ludwig Root - liquid oxygen in a 5,000 Nmc storage tank - liquid oxygen in 500 Nmc LPT - compressed oxygen gas in 10 Nmc cylinders - compressed oxygen gas in 0.4 Nmc cylinders with pressure reducer 4. Oncology Department, 11-13 Vicențiu Babeș St. — permanent operating regime - Liquefied Medical Oxygen LPT 500 nmc - Compressed oxygen gas in 10 Nmc 50 L cylinders 5. UPU Department (2 — 4 Andrenyi Karoly St.) - permanent operating regime - compressed oxygen gas in 0.4 Nmc cylinders with pressure reducer - compressed oxygen gas in 1 Nmc cylinders without pressure reducer - compressed oxygen gas in 2 Nmc cylinders without pressure reducer - Entonox 10 L cylinder 6. Clinical Obstetrics-Gynecology Department (5 Episcopiei St.) -liquid oxygen in 500 Nmc LPT -compressed oxygen gas in 10 Nmc cylinders 7. ENT-OPHTHALMOLOGY Occupational Medicine Department (T. Vladimirescu St.; 9-10 Mihai Viteazu St.) - permanent operating regime -compressed oxygen gas in 10 Nmc cylinders -liquid oxygen in 500 Nmc LPT 8. Psychiatry Department, 13 Cicio Pop St. — permanent operating regime -compressed oxygen gas in 10 Nmc cylinders -compressed oxygen gas in 1 Nmc cylinders with pressure reducer -compressed oxygen gas in 2 Nmc cylinders with pressure reducer 9. Maintenance Workshop -compressed oxygen gas in 10 Nmc cylinders -acetylene b) construction of an automatic backup station; In addition to the actual supply of the products identified above, tenderers in the proc shall consider the design and installation/commissioning of 1 automatic backup station to provide the necessary backu-up in the event of failure of the existing storage/production stations at the SCJUA locations. In this regard, the design and construction of automatic backup stations under the following cond are envisaged 1. backup station (representing an installation with 2 X 10 cylinders) at the SCJUA headquarters, Andrenyi Karoly St., no. 2 - 4, Arad County General characteristics of the station: -it will be intended for use in departments as a backup station -it will provide a continuous flow of medical gases from cylinders having equal capacities and high pressure; -it will be provided with an emergency branch in the event that the two branches (main and secondary) are damaged or empty; -it will have an electronic system for monitoring the station’s operational parameters and for warning/alarming in the event of malfunction; -it will have a galvanized metal housing integrating first-stage pressure reducers, a secondary bypass pressure reducer, isolation valves, overpressure valves, pressure gauges and an alarm system. Technical data: -in accordance with HTM02-01, ISO 7396-1 standards; -suitable for 02, N2O, CO2, Air, N2; -two-stage pressure reduction system, in accordance with ISO 10524-2; -automatic switching from the active branch to the backup branch; -microprocessor-controlled alarm system, in accordance with HTM02-01; -all components that could be exposed to cylinder pressure are tested for resistance to fire-retardant factors, in accordance with ISO 10524-2 and ISO 15001. Procedure: open. Estimated value: 40,013,583.32 RON. Review the original TED notice for the complete requirement, lots, amendments and attachments.
Business details are available after sign in
Codes, capabilities, evidence, buyer details and marketplace actions are withheld from the public HTML and API response.